ETL Systems Piranha PRN-G1S-LS2-008 LNB DC Injector 13 V
  • ETL Systems Piranha PRN-G1S-LS2-008 LNB DC Injector 13 V

ETL Systems Piranha PRN-G1S-LS2-008 LNB DC Injector 13 V

Quantity

Request for Quotation

Your Query is sent.

  •     *Required Fields

Loading

 

Security policy

 

Delivery policy

 

Return policy

ETL Systems Piranha PRN-G1S-LS2-008 LNB DC Injector 13 V

The ETL Systems Piranha PRN-G1S-LS2-008 is an LNB DC power inserter module for satellite communications and RF distribution systems. Operating from 850–2450 MHz, it supplies 13 V DC at port 1 to power a compatible LNB or similar equipment.

The DC output can be switched off, while a selectable 22 kHz tone supports compatible LNB control functions. Maximum LNB load current is 500 mA, with current-limited overcurrent trip and restart protection.

LNB current and RF input power monitoring support user-settable upper and lower alarm limits through the parent chassis. Local monitoring and control are available through the chassis HMI, if fitted, with remote access through the chassis Ethernet interface.

Each hot-swappable module occupies one slot in a compatible GENUS 1U or PRN-G1x chassis. Its compact machined aluminium housing measures 175 × 45 × 20 mm maximum. RF connector options include 50Ω SMA, 50Ω BNC, 75Ω BNC, and 75Ω F-type.

Specifications

Model: PRN-G1S-LS2-008
Product Type: LNB DC power inserter / bias-T
Frequency Range: 850–2450 MHz
Signal Paths: Single path
Chassis Compatibility: GENUS 1U series or PRN-G1x chassis; one slot
RF Connector Options: 50Ω SMA, 50Ω BNC, 75Ω BNC, or 75Ω F-type
Insertion Loss: Less than 1.5 dB across the full band
Flatness: ±0.40 dB full band; ±0.15 dB over any 36 MHz
Return Loss: 17 dB typ.; 14 dB minimum
Module-to-Module Isolation: 80 dB minimum
LNB DC Output: Off or 13 V at port 1; ±5% tolerance typ.
Maximum LNB Load: 500 mA; current-limited overcurrent trip and restart
22 kHz Tone: Switchable on/off
RF Input Power / Detection: +15 dBm absolute total maximum input; −50 to −10 dBm total-power indication range
Power Supply / Consumption: Chassis-supplied dual redundant 12 V DC bus; 12 W full load, 2 W no load, maximum steady-state consumption
Dimensions / Weight / MTBF: 175 × 45 × 20 mm maximum; 0.18 kg; greater than 250,000 hours

Connector Configurations

• PRN-G1S-LS2-008-S5S5: 50Ω SMA

• PRN-G1S-LS2-008-B5B5: 50Ω BNC

• PRN-G1S-LS2-008-B7B7: 75Ω BNC

• PRN-G1S-LS2-008-F7F7: 75Ω F-type

Key Features

• Switchable 13 V DC power for a compatible LNB.

• Up to 500 mA LNB load capacity.

• Selectable 22 kHz tone.

• LNB current and RF input power monitoring.

• User-settable upper and lower current and RF power alarm limits.

• Compact, hot-swappable, single-slot module.

• Local and remote control through the compatible parent chassis.

This listing covers one PRN-G1S-LS2-008 module in the selected connector configuration. The parent chassis, LNB, RF cables, and other accessories are sold separately unless included in the quoted configuration. This model provides 13 V DC output and does not specify 10 MHz reference injection. RF power detection is for indication only. Specifications apply to 50Ω connectors unless otherwise stated. Confirm LNB voltage, current, tone requirements, and chassis power capacity when requesting a quotation.

PRN-G1S-LS2-008

Specific References