Actox ABE100DC
100W Extended C-Band BUC
Output frequency 5.85 - 6.725 GHz
Based on GaN technology which enables high efficiency, low power consumption and high reliability
Local Oscillator 4.9 GHz
Incomparable low power consumption (375W max.)
Auto-ranging powering option 80-240 VAC and optional 48VDC
High power efficiency (100W min. over temperature)
Digital temperature compensation
Field-exchangeable (F/N) IF connector
Security policy
Delivery policy
Return policy
ABE100DC
- Transmit Frequency
- 5.850 - 6.725 GHz
- Input Frequency
- 950 - 1825 MHz
- LO Frequency
- 4.90 GHz
- Power Output
- 100W
- Gain Variation
- +/- 0.5 dB over 40 MHz
- Gain Variation
- +/-1.8 dB over full band
- Noise Power Density
- Rx: -157 dBm/Hz (max.)
- Noise Power Density
- Tx: -66 dBm/Hz (max.)
- Phase Noise
- -115 dBc/Hz max. @ 1 MHz
- Phase Noise
- -55 dBc/Hz max. @ 10 Hz
- Phase Noise
- -85 dBc/Hz max. @ 10 kHz
- Phase Noise
- -75 dBc/Hz max. @ 1 kHz
- Phase Noise
- -95 dBc/Hz max. @ 100 kHz
- Phase Noise
- -65 dBc/Hz max. @ 100 Hz
- Input VSWR
- 2.0:1
- Output VSWR
- 2.0:1
- Gain
- 67 dB min., 75 dB max. Ajustable in 1dB steps, gain range 20dB
- Gain Stability over Temperature
- +/-1.5 dB typ., +/1.8 dB max.
- Power
- 80-240 VAC, 375W max. via MS connector ABD100DC-auto-ranging
- Spurious
- -55 dBc max.
- LO Leakage
- -45 dBm max.
- FSK
- Multiplexed on TX IFL, compatible with Comtech and Paradigm
- Monitor & Control
- M&C Interface: RS-232 & RS-485
- LED Indicator
- RED: Power OK, L.O unlocked
- LED Indicator
- GREEN: L.O. locked and amplifier functioning normally
- Noise Figure max.
- 15 dB
- Dimensions
- 9.45” (L) x 4.72” (W) x 5.5” (H)
- Dimensions
- 240 (L) x 120 (W) x 140 (H) mm
- Weight
- 3.5 kg (7.7 lbs) max.
- Ambient Temperature
- Operating: -40°C to +55°C
- Ambient Temperature
- Storage: -55°C to +85°C