Actox ABE7KXH

7W Extended Ku Band Mini BUC 

Output frequency 13.75-14.50 GHz

Double - L.O. (switchable 12.80 and 13.05 GHz)

Based on GaN technology which enables high efficiency, low energy consumption and high reliability

Incomparable low power consumption (36W max)- can be powered by iDirect or similar modems

Extreme P-Out GaN linearity

Digital temperature compensation

L.O. lock and amplifier LEDs

M&C - combined RS-232/485, FSK, Ethernet (optional)

Field-exchangeable (F/N) IF connector

Quantity

Request for Quotation

Your Query is sent.

  •     *Required Fields

Loading

 

Security policy

 

Delivery policy

 

Return policy

ABE7KXH
Transmit Band
  • 13.75 - 14.50 GHz
Input Band
  • 950–1700 MHz
LO Frequency
  • 13.05 GHz
  • 12.80 GHz
Output Interface
  • Waveguide, WR75 (with Groove)
Requirement for External Reference
  • Via IF Cable, Frequency: 10MHz (sine-wave), Input Power: -5 to +5 dBm @ input port
Power Output
  • 7W
Gain Variation
  • +/- 0.5 dB over 40 MHz
  • +/-1.8 dB over full band
Spectral Regrowth
  • -30 dBc (QPSK at 1.5x and OQPSK at 1.0x symbol rate offset with 2dB back-off from rated output power)
Noise Power Density
  • Tx: -60 dBm/Hz max.
  • Rx: -150 dBm/Hz max.
Phase Noise
  • -73 dBc/Hz @ 1 kHz
  • -83 dBc/Hz @ 10 kHz
  • -93 dBc/Hz @ 100 kHz
  • -63 dBc/Hz @ 100 Hz
  • -53 dBc/Hz max. @ 10 Hz
  • -113 dBc/Hz max @ 1 MHz
Input VSWR
  • 2.0:1
Output VSWR
  • 2.0:1
Gain
  • 60 dB typical
IMD3 (two tones)
  • -26 dBc max. 2 signal 5 MHz apart at P-LINEAR
Gain Stability over Temperature
  • +/-1.5 dB typ., +/1.8 dB max.
Power
  • 15 - 30 VDC via IF cable 36W max.
Spurious
  • -53 dBc max.
LO Leakage
  • -45 dBm max.
Mute
  • Shut off the BUC if L.O. unlocked
LED Indicator
  • RED: Summary alarm
  • GREEN: All OK
  • YELLOW BLINKING: All OK extended L.O. 12.80 GHz
Noise Figure max.
  • 20 dB
Dimensions
  • 140 (L) x 120 (W) x 52 (H) mm
  • 5.6” (L) x 4.8” (W) x 2.08” (H)
Weight
  • 1.3 kg (2.9 lbs) max
Ambient Temperature
  • Operating: -40°C to +55°C
  • Storage: -55°C to +85°C
Shock & Vibration
  • Complies with MIL-STD-810E

Specific References