Representative ETL Falcon downconverter module with cooling fans and RF input and IF output connectors.
  • Representative ETL Falcon downconverter module with cooling fans and RF input and IF output connectors.

ETL Systems FN-D-L1F2-24404AA – 850–3150 MHz to 70/140 MHz Downconverter

Quantity

Request for Quotation

Your Query is sent.

  •     *Required Fields

Loading

 

Security policy

 

Delivery policy

 

Return policy

ETL Systems FN-D-L1F2-24404AA – 850–3150 MHz to 70/140 MHz Downconverter

The ETL Systems Falcon FN-D-L1F2-24404AA converts 850–3150 MHz signals to 70 MHz or 140 MHz IF, with 1 kHz frequency tuning and nominal 5–35 dB variable conversion gain. This hot-swappable, four-slot module uses dual-stage, non-inverting conversion and requires a compatible GENUS chassis for operation, local control and remote monitoring.

Technical Specifications

Model: FN-D-L1F2-24404AA
Input Frequency Range: 850–3150 MHz
Output Frequency Range: 70 ±20 MHz or 140 ±40 MHz
Frequency Step Size: 1 kHz
Conversion Gain: Nominal 5–35 dB; ±2 dB tolerance at minimum and maximum settings
Gain Step Size: 0.1 ±0.1 dB
Gain Flatness: ±0.3 dB, 50Ω configuration
Input / Output Return Loss: 20 dB typ.; 16 dB minimum
Impedance: 50Ω; confirm connector configuration when ordering
Noise Figure: 8 dB typ.; 10 dB maximum, at maximum gain
Maximum Operational Input Level: −30 dBm at maximum gain
Output P1dB: +13 dBm typ.; +10 dBm minimum, at maximum gain
Output IP3: +25 dBm typ.; +22 dBm minimum, at maximum gain
Internal Reference Stability: ±0.05 ppm over 0°C to +50°C
External Reference Input: 10 MHz or 100 MHz with automatic detection; 0 ±10 dBm
Image Rejection: Greater than 60 dB typ.
LO Breakthrough: Less than −75 dBm
Mute Attenuation: 60 dB
Conversion: Dual-stage, non-inverting
Chassis Requirement: Compatible GENUS chassis; four slots per module

Specifications apply to the standalone module. Refer to the manufacturer’s datasheet for complete phase-noise, spurious and redundant-system performance.

Compatibility and Ordering

Supports 1+1 redundancy with SWF-G1S-CX-111A or 2+1 redundancy with SWF-G1S-CX-117, together with the required additional converter modules. System RF performance varies by configuration.

Specify the required IF output, connectors, chassis and redundancy arrangement when requesting a quotation. The full ordering number includes a configuration suffix: FN-D-L1F2-24404AA-XXXX.

This listing covers one downconverter module. The GENUS chassis, redundancy switch, additional modules, external reference source, RF cables and accessories are sold separately unless included in the quoted configuration.