The ETL Systems Falcon FN-D-C1L1-24426AC is a dual-mode block downconverter that converts 3400–4200 MHz to 950–1750 MHz or 3700–4800 MHz to 950–2050 MHz. It provides nominal 0–35 dB variable conversion gain and 0–6 dB slope compensation for signal-level adjustment and frequency-dependent loss correction.
This hot-swappable, four-slot module uses dual-stage, non-inverting conversion and requires a compatible GENUS chassis. Local and remote monitoring and control are provided through the selected chassis.
Technical Specifications
Model: FN-D-C1L1-24426AC
Full Part Number: FN-D-C1L1-24426AC-S5S5
Frequency Modes: User selectable, as shown below
| Mode | Input Frequency Range | Output Frequency Range | Instantaneous Bandwidth |
| 1 | 3400–4200 MHz | 950–1750 MHz | 800 MHz |
| 2 | 3700–4800 MHz | 950–2050 MHz | 1100 MHz |
Conversion Gain: Nominal 0–35 dB; ±1.5 dB tolerance at minimum and maximum settings
Gain Step Size: 0.25 ±0.15 dB
Gain Flatness: ±1.5 dB across the full output band; ±0.3 dB over any 40 MHz
Slope Compensation: 0–6 dB in 1 dB steps; pivot point at 2150 MHz
Input / Output Return Loss: 18 dB typ.; 15 dB minimum
Impedance: 50Ω
Noise Figure: 12 dB typ.; 14 dB maximum, at maximum gain
Maximum Operational Input Level: −30 dBm at maximum gain
Output P1dB: +18 dBm typ.; +15 dBm minimum, at maximum gain
Output IP3: +28 dBm typ.; +25 dBm minimum, at maximum gain
Group Delay Variation: 1 ns typ.; 2 ns maximum, peak-to-peak across the full instantaneous band
Internal Reference Stability: ±0.05 ppm over 0°C to +50°C
External Reference Input: 10 MHz or 100 MHz with automatic detection; 0 ±10 dBm
Image Rejection: 80 dB typ.
LO Breakthrough: Less than −75 dBm
Mute Attenuation: 60 dB
Conversion: Dual-stage, non-inverting
Chassis Requirement: Compatible GENUS chassis; four slots per module
Specifications apply to the standalone module. Refer to the manufacturer’s datasheet for complete phase-noise, spurious and redundant-system specifications. The reference-stability temperature range is not a complete module operating-temperature rating.
Compatibility and Ordering
Supports 1+1 redundancy with SWF-G1S-CX-111A or 2+1 redundancy with SWF-G1S-CX-117, together with the required additional converter modules. RF performance varies by configuration.
Specify the required frequency mode, connector configuration, chassis and redundancy arrangement when requesting a quotation. The RF specification table identifies the full part number as FN-D-C1L1-24426AC-S5S5.
The manufacturer identifies these specifications as preliminary, and a minimum order quantity applies. Confirm final specifications, minimum quantity and availability before ordering.
This listing covers one downconverter module. The GENUS chassis, redundancy switch, additional modules, external reference source, RF cables and accessories are sold separately unless included in the quoted configuration.