ETL Systems FN-U-C2L1-24440AB – 950–1525 MHz to 5850–6425 MHz Upconverter
Security policy
Delivery policy
Return policy
ETL Systems FN-U-C2L1-24440AB – 950–1525 MHz to 5850–6425 MHz Upconverter
The ETL Systems Falcon FN-U-C2L1-24440AB converts 950–1525 MHz L-band signals to 5850–6425 MHz C-band output. It provides nominal 5–35 dB variable conversion gain, IF power monitoring and single-stage, non-inverting frequency conversion.
This hot-swappable, four-slot module requires a compatible GENUS chassis, which provides local and remote monitoring and control. Redundant configurations are supported with the appropriate switches and additional converter modules.
Technical Specifications
Model: FN-U-C2L1-24440AB
Input Frequency Range: 950–1525 MHz
Output Frequency Range: 5850–6425 MHz
Conversion Gain: Nominal 5–35 dB; ±1.5 dB tolerance at minimum and maximum settings
Gain Step Size: 0.25 ±0.15 dB
Gain Flatness: ±1.5 dB across the full IF band; ±0.25 dB over any 40 MHz
Input / Output Return Loss: 18 dB typ.; 14 dB minimum
Impedance: 50Ω; confirm connector configuration when ordering
Noise Figure: 8 dB typ.; 10 dB maximum, at maximum gain
Input Power Range: −75 to −30 dBm
Output P1dB: +12 dBm typ.; +10 dBm minimum, at maximum gain
Output IP2: +33 dBm typ.; +30 dBm minimum, at maximum gain
Output IP3: +22 dBm typ.; +20 dBm minimum, at maximum gain
Internal Reference Stability: ±0.05 ppm over 0°C to +50°C
External Reference Input: 10 MHz or 100 MHz with automatic detection; 0 ±10 dBm
Integrated Phase Jitter: 151.5 fs RMS typ., integrated from 10 kHz to 1 MHz at 6425 MHz
Image Rejection: 60 dB typ.
LO Breakthrough: −60 dBm maximum
IF Power Monitor: Yes
Mute Attenuation: 60 dB
Conversion: Single-stage, non-inverting
Chassis Requirement: Compatible GENUS chassis; four slots per module
Specifications apply to the standalone module. Refer to the manufacturer’s datasheet for complete phase-noise, spurious and redundant-system specifications. The reference-stability temperature range is not a complete module operating-temperature rating.
Compatibility and Ordering
Supports 1+1 redundancy with SWF-G1S-KX-109A or 2+1 redundancy with SWF-G1S-KX-115, together with the required additional converter modules. RF performance varies by configuration.
Specify the required connectors, chassis and redundancy arrangement when requesting a quotation. The full ordering number includes a configuration suffix: FN-U-C2L1-24440AB-XXXX.
The overview mentions variable slope, but the RF specification table does not define a slope adjustment range. Confirm slope capability if required.
This listing covers one upconverter module. The GENUS chassis, redundancy switch, additional modules, external reference source, RF cables and accessories are sold separately unless included in the quoted configuration.