ETL Systems NG-G1S-B3-03 – Modular Noise Generator 50–2500 MHz
  • ETL Systems NG-G1S-B3-03 – Modular Noise Generator 50–2500 MHz

ETL Systems NG-G1S-B3-03 – Modular Noise Generator 50–2500 MHz

SKU: NG-G1S-B3-03

Quantity

Request for Quotation

Your Query is sent.

  •     *Required Fields

Loading

 

Security policy

 

Delivery policy

 

Return policy

NG-G1S-B3-03 Modular RF Noise Generator

The ETL Systems NG-G1S-B3-03 is a single-slot noise generator module covering 50–2500 MHz in a compatible GENUS 1U chassis. It provides broadband noise for RF testing, with maximum integrated output power of +10 ±5 dBm and noise power spectral density of −84 ±5 dBm/Hz.

Attenuation is adjustable over a specified 60 dB range, with up to 85 dB available control. The attenuator provides glitch-free and dropout-free adjustment in 0.25 ±0.25 dB steps. An optional signal injection input supports combining an external signal with the noise output.

Local touchscreen operation and remote Ethernet monitoring and control are provided through the compatible GENUS chassis. Connector configuration and the complete ordering suffix must be specified when requesting a quotation.

Key Features

  • Single-band frequency coverage from 50–2500 MHz.
  • Maximum integrated noise output power of +10 ±5 dBm.
  • Noise power spectral density of −84 ±5 dBm/Hz.
  • 60 dB specified attenuation range; 85 dB available control.
  • Glitch-free and dropout-free attenuation adjustment.
  • Optional signal injection input with 20 dB insertion loss.
  • SMA female or BNC female connector options.
  • Single-slot module; up to 16 noise generator modules per compatible chassis.

Noise Generator Module Specifications

ParameterSpecification
Model NG-G1S-B3-03
Manufacturer ETL Systems
Ordering Designation NG-G1S-B3-03-xxxx; configuration suffix to be confirmed
Product Type Modular broadband RF noise generator
Frequency Range 50–2500 MHz
RF Port Count Two ports listed; signal injection input is optional
Maximum Output Power +10 ±5 dBm over 50–2500 MHz
Noise Power Spectral Density −84 ±5 dBm/Hz
Specified Attenuation Control Range 60 dB
Available Attenuation Control Range 85 dB; output power specifications may not be met above 60 dB attenuation
Attenuation Steps 0.25 ±0.25 dB
Attenuator Type Glitch-free and dropout-free
Output Power Flatness ±3 dB
Signal Injection Port Loss 20 dB
Output Return Loss 14 dB typ.; 10 dB minimum
Input Return Loss 14 dB typ.; 10 dB minimum
Muted Output Power Spectral Density −160 dBm/Hz
Output Connector SMA female or BNC female
Optional Input Connector SMA female or BNC female
Maximum DC Voltage Applied to Output Connector 50 V DC
Control Method Via compatible GENUS chassis
Module Width One slot
Maximum Noise Generator Modules per Chassis 16
Module Operating Temperature 0°C to +50°C; subject to chassis limits
Module Storage Temperature −20°C to +75°C
Installation Environment Indoor use only
Relative Humidity 20–90%, non-condensing
Module Altitude Rating 10,000 ft / 3000 m above mean sea level; subject to chassis limits
Module Weight Not specified; listed as TBA

Compatible GENUS 1U Chassis Specifications

The following specifications apply to the chassis platform described in the datasheet. They are not standalone module specifications.

ParameterSpecification
Dimensions 1U high × 550 mm deep × 19 inches wide
Weight Less than 10 kg
Colour RAL 9003 white, semi-matte
Chassis Capacity 17 module slots; noise generator module count limited to 16 as specified above
Operating Temperature 0°C to +45°C
Storage Temperature −20°C to +75°C
Installation Environment Indoor use only
Relative Humidity 20–90%, non-condensing
Operating Altitude 2000 m above mean sea level
Storage Altitude 8000 m above mean sea level
Local Control HMI capacitive touchscreen
Remote Interface RJ45 Ethernet; 10BaseT/100BaseTX
Control Protocols ETL TCP/IP, SNMPv2/v3, HTTPS and built-in web server
Serviceable Control Components Field-replaceable HMI and CPU
AC Input 85–264 V AC, 50/60 Hz
Maximum Steady-State Power Consumption 275 W
Power Supply Redundancy Dual redundant, alarmed, diode-OR, hot-swappable power supplies
Mean Time to Repair 20 minutes for line-replaceable units, assuming an on-site spare: 15 minutes to retrieve and 5 minutes to replace
RF Input and Output Ports Depend on the installed module configuration

Configuration and Ordering Notes

This listing covers one NG-G1S-B3-03 noise generator module. The GENUS chassis, optional signal injection configuration, cables and other accessories are supplied only when included in the quotation.

At attenuation settings above 60 dB, noise output approaches the thermal noise floor of −174 dBm/Hz, and the specified noise output performance may not be maintained. The available 85 dB control range should not be interpreted as an 85 dB range of guaranteed output performance.

The module and chassis have different temperature and altitude ratings. The complete installation must remain within the limits of every installed component. Although the datasheet overview mentions outdoor chassis options, the tabulated module and chassis specifications state indoor use only; confirm any outdoor installation with ETL Systems.

Specify the connector type, optional signal injection input, chassis requirements and complete model suffix when requesting a quotation.

NG-G1S-B3-03

Specific References