ETL Systems SG-G1S-B3-01 – Modular RF Signal Generator 25–3000 MHz
Security policy
Delivery policy
Return policy
SG-G1S-B3-01 Modular RF Signal Generator
The ETL Systems SG-G1S-B3-01 is a modular RF signal generator covering 25–3000 MHz in 100 Hz frequency steps. It provides adjustable output power from −15 to +13 dBm, with 0.5 dB adjustment steps and a specified step tolerance of ±0.2 dB.
The module features an SMA female RF connector, 10 MHz reference input and 100 MHz reference output. Internal reference stability is ±1 ppm. Frequency lock time is less than 50 ms.
Designed for a compatible GENUS 1U or Instrumentation Benchtop Chassis, each module occupies four slots. Local and remote monitoring and control are provided through the selected chassis, with touchscreen operation where fitted and web browser access through the chassis Ethernet interface.
Key Features
- 25–3000 MHz frequency coverage with 100 Hz steps.
- Adjustable RF output power from −15 to +13 dBm.
- Output power adjustment in 0.5 ±0.2 dB steps.
- Internal reference stability of ±1 ppm.
- 10 MHz reference input and 100 MHz reference output.
- SMA female RF and reference connections.
- Frequency lock time below 50 ms.
- Four-slot module for compatible GENUS 1U or Instrumentation Benchtop Chassis.
Signal Generator Module Specifications
| Parameter | Specification |
|---|---|
| Model | SG-G1S-B3-01 |
| Manufacturer | ETL Systems |
| Ordering Designation | SG-G1S-B3-01-S5 is identified in the datasheet overview; confirm the complete configuration suffix |
| Product Type | Modular RF signal generator |
| Frequency Range | 25–3000 MHz |
| Frequency Step Size | 100 Hz |
| Output Power Range | −15 to +13 dBm |
| Output Power Adjustment Steps | 0.5 ±0.2 dB |
| Internal Reference Stability | ±1 × 10−6 (±1 ppm); equivalent to ±0.1 kHz at 100 MHz |
| In-Band Non-Carrier-Related Spurs | Less than −60 dBm |
| Carrier-Related Spurs | Less than −50 dBc |
| Harmonics | Less than −20 dBc at +10 dBm output power |
| Lock Time | Less than 50 ms |
| RF Connector | SMA female |
| Reference Connector | SMA female |
| Reference Input Frequency | 10 MHz |
| Reference Output Frequency | 100 MHz |
| Power Selection | Automatic switching, as stated in the datasheet |
| Control Method | Via compatible chassis; local and remote control provided by the chassis |
| Chassis Compatibility | GENUS 1U or Instrumentation Benchtop Chassis |
| Module Slot Requirement | Four slots per module |
| Modules per Chassis | Four, as specified in the datasheet; confirm capacity for the selected chassis |
| Maximum DC Voltage Applied to Output Connector | 50 V DC |
| Module Operating Temperature | −20°C to +50°C; subject to chassis limits |
| Module Storage Temperature | −40°C to +85°C; subject to chassis limits |
| Installation Environment | Indoor use only |
| Relative Humidity | 20–90%, non-condensing |
| Module Altitude Rating | 10,000 ft / 3000 m above mean sea level; subject to chassis limits |
| Module Dimensions | 114 × 70 × 20 mm |
| Module Weight | 0.35 kg |
Typical Phase Noise
| Offset Frequency | 25–1000 MHz | 1000–3000 MHz |
|---|---|---|
| 1 kHz | −98 dBc/Hz | −92 dBc/Hz |
| 10 kHz | −96 dBc/Hz | −94 dBc/Hz |
| 100 kHz | −106 dBc/Hz | −101 dBc/Hz |
GENUS 1U Chassis Specifications
The following specifications apply to the rackmount chassis described in the datasheet. Confirm separate specifications for an Instrumentation Benchtop Chassis.
| Parameter | Specification |
|---|---|
| Dimensions | 1U high × 550 mm deep × 19 inches wide |
| Weight | Less than 10 kg |
| Colour | RAL 9003 white, semi-matte |
| Capacity | 17 module slots; each signal generator module requires four slots |
| Operating Temperature | 0°C to +45°C |
| Storage Temperature | −20°C to +75°C |
| Installation Environment | Indoor use only |
| Relative Humidity | 20–90%, non-condensing |
| Operating Altitude | 2000 m above mean sea level |
| Storage Altitude | 8000 m above mean sea level |
| Local Control | HMI capacitive touchscreen, where fitted |
| Remote Interface | RJ45 Ethernet; 10BaseT/100BaseTX |
| Control Protocols | ETL TCP/IP, SNMPv2/v3, HTTPS and built-in web server |
| Serviceable Control Components | Field-replaceable HMI and CPU |
| AC Input | 85–264 V AC, 50/60 Hz |
| Maximum Steady-State Power Consumption | 275 W |
| Power Supply Redundancy | Dual redundant, alarmed, diode-OR, hot-swappable power supplies |
| Mean Time to Repair | 20 minutes for line-replaceable units, assuming an on-site spare: 15 minutes to retrieve and 5 minutes to replace |
| Input and Output Ports | Depend on the installed module configuration |
Configuration and Ordering Notes
This listing covers one SG-G1S-B3-01 signal generator module. The compatible chassis, external reference source, cables and other accessories are sold separately unless included in the quoted configuration.
The V1.0 datasheet contains overview callouts referring to 50–2500 MHz, noise power spectral density and attenuation ranges that conflict with its signal generator specification table. This listing uses the 25–3000 MHz frequency range, −15 to +13 dBm output power range and other values in the dedicated signal generator RF parameter table.
The module and chassis have different environmental ratings. The complete system must operate within the limits of all installed components. Confirm the complete ordering suffix, chassis configuration and the meaning of the datasheet's “Power selection: Automatic switching” entry when requesting a quotation.