ETL Systems SG06-840002 – Miniature RF Signal Generator 25–6000 MHz
Security policy
Delivery policy
Return policy
SG06-840002-S5S5 Miniature RF Signal Generator
The ETL Systems SG06-840002-S5S5 is a miniature RF signal generator covering 25–6000 MHz with 1 Hz frequency resolution. Output power is adjustable in 0.5 dB steps, from −17 to +13 dBm below 3 GHz and from −17 to +10 dBm across 3–6 GHz.
Continuous output, sweep operation and externally triggered RF on/off modes support RF test applications. USB, Ethernet and RS-232 interfaces provide control through the supplied graphical software or ASCII commands. Non-volatile memory automatically stores the most recent settings.
The generator includes an internal 100 MHz reference and accepts a software-selectable 10 MHz or 100 MHz external reference. Its SMA female reference port automatically detects and switches between reference input and output operation. Control software, a USB-to-mini-USB cable and an AC power supply adaptor are included.
Key Features
- 25–6000 MHz frequency coverage with 1 Hz tuning steps.
- Maximum output of +13 dBm below 3 GHz and +10 dBm across 3–6 GHz.
- Output level adjustment in 0.5 dB steps, down to −17 dBm.
- Continuous, sweep and externally triggered RF output modes.
- USB virtual COM port, RJ45 Ethernet and RS-232 control.
- SMA female RF output and reference connections.
- Internal 100 MHz reference or external 10/100 MHz reference input.
- 9–28 V DC or USB 3.0 power with automatic source switching.
- Compact aluminium enclosure weighing 350 g.
RF Specifications
| Parameter | Specification |
|---|---|
| Product Model / SKU | SG06-840002-S5S5 |
| Base Model | SG06-840002 |
| Manufacturer | ETL Systems |
| Series | SG Series miniature signal generators |
| Frequency Range | 25–6000 MHz |
| Frequency Step Size | 1 Hz |
| Output Power Range Below 3 GHz | −17 to +13 dBm |
| Output Power Range at 3–6 GHz | −17 to +10 dBm |
| Output Level Adjustment | 0.5 dB steps; level set in dBm |
| Internal Reference Frequency | 100 MHz |
| Internal Reference Temperature Stability | ±20 ppm over temperature; equivalent to ±2 kHz at 100 MHz |
| Internal Reference Ageing | ±1 ppm per year; ±3 ppm in the first year |
| Spurious | Maximum: less than −50 dBc; typ.: less than −70 dBc |
| Harmonics | Maximum: −20 dBc; typ.: −25 dBc |
| RF Output Connector | SMA female |
| Reference Connector | SMA female; automatic reference input/output detection and switching |
| Reference Output | 100 MHz |
| External Reference Input | 10 MHz or 100 MHz, software selectable |
| External Reference Input Level | −4 to +12 dBm |
Maximum Phase Noise
| Output Frequency Range | 1 kHz Offset | 10 kHz Offset | 100 kHz Offset |
|---|---|---|---|
| 25–250 MHz | Not clearly specified | −106 dBc/Hz | −112 dBc/Hz |
| 250–1000 MHz | −98 dBc/Hz | −96 dBc/Hz | −106 dBc/Hz |
| 1000–3000 MHz | −92 dBc/Hz | −94 dBc/Hz | −101 dBc/Hz |
| 3000–6000 MHz | −83 dBc/Hz | −85 dBc/Hz | −92 dBc/Hz |
The V2.1 datasheet has a misaligned 1 kHz-offset column: the word “Offset” occupies the first frequency row, followed by three numerical entries. The table above preserves their printed row alignment. Confirm the complete 1 kHz-offset specifications with ETL Systems if required for system qualification.
Control and Interface Specifications
| Parameter | Specification |
|---|---|
| USB Interface | Virtual COM port |
| RS-232 Interface | 9-pin male D-sub connector |
| Ethernet Interface | RJ45 connector |
| Output Modes | Continuous, sweep and RF on/off via external trigger |
| External Trigger Connection | Pin 4 of the RS-232 connector |
| External Trigger Signal | TTL/RS-232 pulse levels; minimum pulse width 50 ms |
| Manual Trigger | Available through the graphical user interface |
| Status Indicators | Power, lock, RF output and reference output |
| Terminal Control | ASCII commands through a compatible third-party terminal application |
| Graphical Software Functions | Frequency and output level adjustment, reference frequency selection, operating mode selection, power-on defaults, sweep configuration, network settings and multiple-unit control |
| Internal Memory | Non-volatile; automatically stores the most recent settings |
Power, Environmental and Mechanical Specifications
| Parameter | Specification |
|---|---|
| DC Input | 9–28 V DC |
| Included AC Power Adaptor | 12 V, 3 A; 1.20 m lead |
| Typical Current Consumption at 12 V | 300 mA |
| USB Power | USB 3.0; 860 mA typ. at 5 V |
| Power Selection | Automatic; coaxial DC power jack takes priority, with USB power used when DC jack power is absent |
| Operating Temperature | −20°C to +50°C |
| Storage Temperature | −40°C to +85°C |
| Dimensions | 163 × 103 × 30.5 mm |
| Weight | 350 g |
| Enclosure | Aluminium extrusion with aluminium endplates and black legends |
| Feet | Rubber feet |
| Included Items | Control software, USB-to-mini-USB cable and AC power supply adaptor |
| Optional Accessory | OPT06 mounting bracket pair; supplied fitted to the unit when ordered |
Configuration and Ordering Notes
This listing covers the SG06-840002-S5S5 miniature signal generator with the included items identified above. The optional OPT06 mounting bracket pair and other accessories are supplied only when included in the quotation.
The detailed V2.1 specification table states internal reference stability of ±20 ppm over temperature and ageing of ±1 ppm per year, with ±3 ppm in the first year. The overview's ±1 ppm reference callout should not be interpreted as the temperature stability rating.
Specify external reference requirements, control interface and any mounting accessories when requesting a quotation.