Filter by

Type
more... less
Redundancy
more... less
Frequency Band
more... less
Frequency Range
more... less
Number of Bands
more... less
Sub-Band
more... less
LO Stability
more... less
Noise Figure
more... less
Output Connector
more... less
Manufacturers

Brands

Brands

LNBs

Explore Esatcom Inc.’s comprehensive selection of Low Noise Block Downconverters (LNBs) for C, X, Ku, and Ka-band satellite communications. Our LNBs include single, multi-band, band-switching, and high-stability models designed for commercial, military, broadcast, and mobility applications. Whether you need precision for fixed installations or robust performance for mobile terminals, we offer reliable LNB solutions from industry-leading manufacturers. Filter by frequency, polarization, gain, and noise figure to find the ideal product for your uplink or downlink chain.

  • Nisshinbo NJS8486H

    Palapa C-Band PLL LNB

    • Input Band: 3.4–4.2 GHz

    • LO Stability: ±10 ppm (±50 kHz)

    • Noise Temperature: 15K

    ⚠️ End of Life Notice

    The models are end-of-life (EOL) and have been replaced by the NJS8496HF and NJS8496HN.

  • Nisshinbo NJR2843E

    Universal Ku-band 2LO PLL LNB - Input Voltage (High/Low)

    Covers 10.70–12.75 GHz in two sub-bands:

    • Band 1: 10.70–11.70 GHz

    • Band 2: 11.70–12.75 GHz

    • LO Stability: Depends on External Reference

    • Noise Figure: 0.8 dB

    • Output Connector: F-type, 75 Ω

  • Nisshinbo NJR2842E

    Universal Ku-band 2LO PLL LNB - 22 kHz Tone On/Off

    Covers 10.70–12.75 GHz in two sub-bands:

    • Band 1: 10.70–11.70 GHz

    • Band 2: 11.70–12.75 GHz

    • LO Stability: Depends on External Reference

    • Noise Figure: 0.8 dB

    • Output Connector: F-type, 75 Ω

  • Nisshinbo NJR2843S

    Universal Ku-band 2LO PLL LNB - Input Voltage (High/Low)

    Covers 10.70–12.75 GHz in two sub-bands:

    • Band 1: 10.70–11.70 GHz

    • Band 2: 11.70–12.75 GHz

    • LO Stability: ±3 ppm (±30 kHz)

    • Noise Figure: 0.8 dB

    • Output Connector: F-type, 75 Ω

  • Nisshinbo NJR2842S

    Universal Ku-band 2LO PLL LNB - 22 kHz Tone On/Off

    Covers 10.70–12.75 GHz in two sub-bands:

    • Band 1: 10.70–11.70 GHz

    • Band 2: 11.70–12.75 GHz

    • LO Stability: ±3 ppm (±30 kHz)

    • Noise Figure: 0.8 dB

    • Output Connector: F-type, 75 Ω

  • Nisshinbo NJR2843H

    Universal Ku-band 2LO PLL LNB - Input Voltage (High/Low)

    Covers 10.70–12.75 GHz in two sub-bands:

    • Band 1: 10.70–11.70 GHz

    • Band 2: 11.70–12.75 GHz

    • LO Stability: ±10 ppm (±100 kHz)

    • Noise Figure: 0.8 dB

    • Output Connector: F-type, 75 Ω

  • Nisshinbo NJR2842H

    Universal Ku-band 2LO PLL LNB - 22 kHz Tone On/Off

    Covers 10.70–12.75 GHz in two sub-bands:

    • Band 1: 10.70–11.70 GHz

    • Band 2: 11.70–12.75 GHz

    • LO Stability: ±10 ppm (±100 kHz)

    • Noise Figure: 0.8 dB

    • Output Connector: F-type, 75 Ω

  • Nisshinbo NJR2841H

    Universal Ku-band 2LO PLL LNB - Mechanical Switch

    Covers 10.70–12.75 GHz in two sub-bands:

    • Band 1: 10.70–11.70 GHz

    • Band 2: 11.70–12.75 GHz

    • LO Stability: ±10 ppm (±100 kHz)

    • Noise Figure: 0.8 dB

    • Output Connector: F-type, 75 Ω

  • Nisshinbo NJR2843L

    Universal Ku-band 2LO PLL LNB - Input Voltage (High/Low)

    Covers 10.70–12.75 GHz in two sub-bands:

    • Band 1: 10.70–11.70 GHz

    • Band 2: 11.70–12.75 GHz

    • LO Stability: ±50 ppm (±500 kHz)

    • Noise Figure: 0.8 dB

    • Output Connector: F 75 Ohm or N 50 Ohm

    ⚠️ End of Life Notice

    The models are end-of-life (EOL) and have been replaced by the NJR2843H and NJR2843HN.

  • Nisshinbo NJR2842L

    Universal Ku-band 2LO PLL LNB - 22 kHz Tone On/Off

    Covers 10.70–12.75 GHz in two sub-bands:

    • Band 1: 10.70–11.70 GHz

    • Band 2: 11.70–12.75 GHz

    • LO Stability: ±50 ppm (±500 kHz)

    • Noise Figure: 0.8 dB

     Output Connector: F 75 Ohm or N 50 Ohm

    ⚠️ End of Life Notice

    The models are end-of-life (EOL) and have been replaced by the NJR2842H and NJR2842HN.

  • Nisshinbo NJR2841L

    Universal Ku-band 2LO PLL LNB - Mechanical Switch

    Covers 10.70–12.75 GHz in two sub-bands:

    • Band 1: 10.70–11.70 GHz

    • Band 2: 11.70–12.75 GHz

    • LO Stability: ±50 ppm (±500 kHz)

    • Noise Figure: 0.8 dB

    • Output Connector: F 75 Ohm or N 50 Ohm

    ⚠️ End of Life Notice

    The models are end-of-life (EOL) and have been replaced by the NJR2841H and NJR2841HN.

  • Nisshinbo NJR2939E

    Ku-band PLL LNB (11.2–11.7 GHz, External 10 MHz Ref)

    • Input Band: 11.2–11.7 GHz

    • LO Stability: Depends on External Reference

    • Noise Figure: 0.8 typ.

    ⚠️ End of Life Notice

    The models are end-of-life (EOL) and have been replaced by the NJR2845DEF and NJR2845DEN.

  • Nisshinbo NJR2937E

    Ku-band PLL LNB (10.95–11.7 GHz, External 10 MHz Ref)

    • Input Band: 10.95–11.7 GHz

    • LO Stability: Depends on External Reference

    • Noise Figure: 0.8 typ.

    ⚠️ End of Life Notice

    The models are end-of-life (EOL) and have been replaced by the NJR2845AEF and NJR2845AEN.

  • Nisshinbo NJR2936E

    Ku-band PLL LNB (12.25–12.75 GHz, External 10 MHz Ref)

    • Input Band: 12.25–12.75 GHz

    • LO Stability: Depends on External Reference

    • Noise Figure: 0.8 typ.

    ⚠️ End of Life Notice

    The models are end-of-life (EOL) and have been replaced by the NJR2845CEF and NJR2845CEN.

  • Nisshinbo NJR2934E

    Ku-band PLL LNB (12.2–12.75 GHz, External 10 MHz Ref)

    • Input Band: 12.2–12.75 GHz

    • LO Stability: Depends on External Reference

    • Noise Figure: 0.8 typ.

    ⚠️ End of Life Notice

    The models are end-of-life (EOL) and have been replaced by the NJR2845GEF and NJR2845GEN.

  • Nisshinbo NJR2935E

    Ku-band PLL LNB (11.7–12.2 GHz, External 10 MHz Ref)

    • Input Band: 11.7–12.2 GHz

    • LO Stability: Depends on External Reference

    • Noise Figure: 0.8 typ.

    ⚠️ End of Life Notice

    The models are end-of-life (EOL) and have been replaced by the NJR2845BEF and NJR2845BEN.