LNBs
Explore Esatcom Inc.’s comprehensive selection of Low Noise Block Downconverters (LNBs) for C, X, Ku, and Ka-band satellite communications. Our LNBs include single, multi-band, band-switching, and high-stability models designed for commercial, military, broadcast, and mobility applications. Whether you need precision for fixed installations or robust performance for mobile terminals, we offer reliable LNB solutions from industry-leading manufacturers. Filter by frequency, polarization, gain, and noise figure to find the ideal product for your uplink or downlink chain.
-
Norsat 3200F-sBPF-4 C-Band...
$3,080.00• Input Band 1: 3.4 – 4.2 GHz
• Input Band 2: 3.8 – 4.2 GHz
• LO Stability: ±25 kHz
• Noise Temperature: 37 K
• Output Connector: F-type, 75 Ω
-
Norsat 3500F-sBPF-4 C-Band...
$2,860.00• Input Band 1: 3.4 – 4.2 GHz
• Input Band 2: 3.8 – 4.2 GHz
• LO Stability: ±100 kHz
• Noise Temperature: 37 K
• Output Connector: F-type, 75 Ω
-
Norsat 3500F-sBPF-6 C-Band...
$2,860.00• Input Band 1: 3.4 – 4.2 GHz
• Input Band 2: 4.0 – 4.2 GHz
• LO Stability: ±100 kHz
• Noise Temperature: 37 K
• Output Connector: F-type, 75 Ω
-
Norsat 3500F-sBPF-5 C-Band...
$2,860.00• Input Band 1: 3.4 – 4.2 GHz
• Input Band 2: 3.9 – 4.2 GHz
• LO Stability: ±100 kHz
• Noise Temperature: 37 K
• Output Connector: F-type, 75 Ω
-
Norsat 3100N-sBPF-4 C-Band...
$3,300.00• Input Band 1: 3.4 – 4.2 GHz
• Input Band 2: 3.8 – 4.2 GHz
• LO Stability: ±10 kHz
• Noise Temperature: 37 K
• Output Connector: N-type, 50 Ω
-
Norsat 3100N-sBPF-5 C-Band...
$3,300.00• Input Band 1: 3.4 – 4.2 GHz
• Input Band 2: 3.9 – 4.2 GHz
• LO Stability: ±10 kHz
• Noise Temperature: 37 K
• Output Connector: N-type, 50 Ω
-
Norsat 3100N-sBPF-6 C-Band...
$3,300.00• Input Band 1: 3.4 – 4.2 GHz
• Input Band 2: 4.0 – 4.2 GHz
• LO Stability: ±10 kHz
• Noise Temperature: 37 K
• Output Connector: N-type, 50 Ω
-
Norsat 3200N-sBPF-4 C-Band...
$3,080.00• Input Band 1: 3.4 – 4.2 GHz
• Input Band 2: 3.8 – 4.2 GHz
• LO Stability: ±25 kHz
• Noise Temperature: 37 K
• Output Connector: N-type, 50 Ω
-
Norsat 3500N-sBPF-4 C-Band...
$2,860.00• Input Band 1: 3.4 – 4.2 GHz
• Input Band 2: 3.8 – 4.2 GHz
• LO Stability: ±100 kHz
• Noise Temperature: 37 K
• Output Connector: N-type, 50 Ω
-
Norsat 3500N-sBPF-5 C-Band...
$2,860.00• Input Band 1: 3.4 – 4.2 GHz
• Input Band 2: 3.9 – 4.2 GHz
• LO Stability: ±100 kHz
• Noise Temperature: 37 K
• Output Connector: N-type, 50 Ω
-
Norsat 3500N-sBPF-6 C-Band...
$2,860.00• Input Band 1: 3.4 – 4.2 GHz
• Input Band 2: 4.0 – 4.2 GHz
• LO Stability: ±100 kHz
• Noise Temperature: 37 K
• Output Connector: N-type, 50 Ω
-
SMW X LNB 7.75-8.50 GHz 1...
• 7.75-8.50 GHz
• External reference with fallback to Internal reference
• Alarm, Monitoring & Control as standard
-
SMW Ka LNB 25.50-27.00 GHz...
• Frequency range 25.50-27.00 GHz
• Auto LO ref Ext. 10 MHz, fallback to Internal ref
• High P1dB and IP3
• Wide operating temperature range
• Enclosure fixing points
• Alarm and Monitoring & Control via Modbus RTU RS485
-
SMW Ka LNB 27.00-31.00 GHz...
• Single LO models within 27.00-31.00 GHz
• Auto Switch between External or Internal ref.
• Low power consumption
• Alarm and Monitoring & Control as standard
-
SMW Ku LNB 12.70–15.50 GHz...
• Auto-switch external 10 MHz reference with fallback to Internal reference
• Single Band or Multiband
• Input frequency range 12.70–15.50 GHz
• Excellent Phase Noise
• Alarm and Monitoring & Control
• Available band / LO Frequency:
12.7–14.2 GHz / 11.75 GHz
12.75–14.25 GHz / 11.8 GHz
13.0–14.5 GHz / 12.0 GHz
13.45–14.95 GHz / 12.5 GHz
13.5–15.0 GHz / 12.55 GHz
13.75–15.25 GHz / 12.8 GHz
13.95–15.45 GHz / 13.0 GHz
14.0–15.5 GHz / 13.05 GHz
14.05–15.5 GHz / 13.1 GHz
14.9–15.5 GHz / 13.2 GHz
14.5–15.5 GHz / 13.5 GHz
• Any combination of above LOs or customized, max 8 Bands
-
SMW Q LNB 37.50-42.50 GHz 1...
• Input frequency range 37.50 to 42.50 GHz
• External reference with fallback to Internal ref.
• Low phase noise and noise figure
• Standard IF frequency output
• Monitoring & Control interface as standard
• Automatic temperature Gain compensation